Service difficulty report · Contactor · Bombdr DHC8402

Difficulty date
August 28, 2013
Submitted
September 3, 2013
Operation
Air carrier
Aircraft
N411QX
Make and model
Bombdr DHC8402
Aircraft serial
4055
Aircraft time
28,640 hours, 29,874 cycles
Part
Contactor
Part number
MS24376D1
Condition
Malfunctioned
Location
Nr 1 Isolator
Stage of operation
CL
How discovered
O
Nature of condition
G
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKEOFF, LT AC BUS, LT TRU, PETOT HEAT 1, & PUSH SYS FAIL CAUTION LIGHTS ILLUMINATED. RETURNED TO FIELD. AFTER LANDING, NR 1 STALL SYS FAIL AND NR 2 STALL SYS FAIL CAUTION LIGHTS ILLUMINATED. C/W FIM 24-21-00-810-801, R & R THE NR 1 ISOLATOR CONTACTOR IAW TASK 30-61-16-000-802 & 30-61-16-400-802, OPS TEST OF AC VARIABLE SYS GOOD, OPS TEST OF PROP DE-ICE SYS GOOD, OPS TEST OF DC SYS GOOD. PERFORMED AN OPS TEST OF THE STALL PROTECTION MODULE IAW T/C 6273301. OPS CHECK GOOD. A/C REMAINS CAT III QUALIFIED, COCK PIT PLACARD REMAINS CAT III, MX CONTROL NR 68530 HAS BEEN NOTIFIED. C/W OPS TEST OF STALL WARN/PUSHER OPS TEST IAW AMM TASK 27-33-00-710-802. NO DFECTS, NO FAULTS, NO CAUTIONS.