What was found
EVIDENCE OF SURFACE CORROSION DETECTED ON LONGITUDINAL STRAP BETWEEN STR 31L AND 32L FROM FS X196.0 TO FS X216.0. REMOVED 5 EA SCREWS TO DISPLACE TRAY FROM FS X196 TO FS X216 REF SRM 51-41-00 TO FOM. INSTALLED 5 EA SCREWS AT TRAY FROM FS X196 TO FS X216 REF SRM 51-41-00. REMOVED 17 EA RIVETS FROM INTERNAL STRAP BETWEEN STA FS X196.00 TO FS X216.00, STRG 31L AND 32L, REF SRM 51-42-05. INSTALLED RIVETS 17 EA TO INTERNAL STRAP BETWEEN STA FS X196.00 TO FS X216.00, STRG 31L AND 32L REF SRM 51-42-05. BLENDED OUT CORROSION ON INTERNAL STRAP BETWEEN FS 196.00 TO FS X216.00 REF SRM 53-00-00, TR 53-019 1 THRU 6A-B. NDT IAW NDTM 51-00-04, 51-00-06 NO DEFECTS LOWEST REMAINING THICKNESS .051. ORIGINAL THICKNESS 0.050", NDT FOUND NO MATERIAL LOSS, FOUND TO BE WITHIN LIMITS IAW SRM 53-00-00. RESTORED FINISH TO INTERNAL SURFACE AREA IAW SRM 51-25-25. RESTORED FINISH TO EXTERIOR SURFACE IAW SRM 51-25-05.