What was found
SURFACE CORROSION DETECTED AT INTERSECTION OF STR 31L AND CIRCUMFERENTIAL STRAP AT THE FWD SIDE OF FS X236.0. REMOVED 4(EA) RIVETS FROM DOUBLER FOM SRM 51-42-05. INSTALLED RIVETS 4(EA) IN DOUBLER AT FS X234.00 Y9.00 REF SRM 51-42-05. REMOVED 4EA CORRODED RIVETS FROM STR31 AT FS X234, Y9.250 REF SRM 51-42-05. INSTALLED RIVETS 4 EA AT FS X234.00 Y9.250 REF SRM 51-42-05. BLENDED OUT CORROSION ON DOUBLER AND INTERNAL STRAP AT FS X234 TO FS X224 AT Y9.0 REF SRM 51-21-00 AND SRM 53-00-00, TR 53-019 NDT IAW NDTM 51-00-04, 51-00-06 NO DEFECTS MIN REMAINING THICKNESS .048. ORIGINAL MATERIAL THICKNESS 0.050 IAW SRM 53-20-31. MATERIAL REMOVED 0.002 IN LIMITS SRM 53-00-00, TR 53-019. RESTORED INTERIOR SURFACE AREA IAW SRM 51-25-25. NDT IAW NDTM 51-00-04, 51-00-06 NO DEFECTS MIN REMAINING THICKNESS .048. JOINT DOUBLER, PN :85360329 IS 0050" THICK MATERIAL REMAINING AFTER BLENDOUT IAW NDT REPORT IS 0.048" AND WITHIN LIMITS IAW SRM 53-00-00. RESTORED FINISH TO EXTERIOR SURFACE AREA AT FS X234.00 TO FS X238.00 IAW SRM 51-25-05 APPLIED CPC TO BLENDED AREA ON THE INSIDE SURFACE OF FUSELAGE IAW AMM 51-25-01-390-801.