What was found
EVIDENCE OF SURFACE CORROSION DETECTED ON LONGITUDINAL STRAP BETWEEN FS X19.40 AND FS 132.40 BETWEEN STRINGERS 31L AND 32L. REMOVED 37 RIVETS BETWEEN F.S. X+19.40 AND X38.400 ON STR 31 LT SRM 51-42-05. INSTALLED 37 RIVETS BETWEEN FS X+19.40 AND 38.400 ON STR 31 LEFT IAW SRM 51-42-05. REMOVED LIGHT CORROSION IAW SRM 51-21-00. NO MATERIAL LOST. RESTORED FINISH IAW SRM 51-25-25. RESTORED FINISH TO EXTERIOR SURFACE AT STR 31L & 32L BETWEEN FS X+19.40 & FS X+32.40 IAW SRM 51-25-05.