What was found
SEAT TRACK, NR 15 IS PITTED. BLENDED SEAT TRACK 15, FS 612-620, RT CENTER REF SRM 53-20-49 FIG 1. EVALUATED BLEND AT SEAT TRACK 15 RT CENTER MATERIAL REMOVED ON TOP PORTION OF CLAW IS .009". ORIGINAL THICKNESS .460" FOUND WITHIN LIMITS REF SRM 53-20-49. C/W ET INSP ON REWORKED AREA REF NDTM PT1 51-00-06. NO DEFECTS NOTED. RESTORED FINISH, SRM 51-21-10.