What was found
FUEL PANEL 524AT HAS CORROSION ON MATING SURFACE. REMOVED DAMAGE AT MARKED AREA ON PANEL 524AT MATING SURFACE, REF SRM 57-20-35. PERFORMED E/T AND U/T INSP ON PANEL 524AT BLEND OUTS IAW NDTM 51-00-04 AND 51-00-06 THICKNESS IS .118-.128. NO DEFECTS NOTED. RESTORED FINISH ON FUEL PANEL 524AT IAW SRM 57-20-35, STEP 7A, ITEMS 5 & 7. REMAINING MATERIAL THICKNESS OF FUEL PANEL 524AT AT BLEND AREAS IS .118-.128 IAW NDT REPORT, MINIMUM ALLOWABLE IS .105 IAW SRM 57-20-35. PANEL 524AT WITHIN ALLOWABLE LIMITS.