As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO FLOOR SHEAR WEB ANGLE HAS SUSPECTED CORROSION. BLENDED ANGLE IAW SRM 53-40-15-02-01. FOUND TO BE WITHIN LIMITS IAW SRM 53-40-15-02-01. BLENDED AREA ALODINED IAW SRM 51-21-10-02-01, PRIMED IAW SRM 51-25-10-02-01 AND PAINTED IAW SRM 51-25-15-02-01. PERFORMED ECI ON ANGLE. NO CRACKS FOUND IAW NDTM PN 6 51-00-01.