As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO BAY FLOOR WEB CORRODED. BLENDED IAW SRM 53-40-43-02-01. PERFORMED FPI OF BLENDED AREA IAW NDTM 51-00-01, NO DEFECTS NOTED. BLENDS FOUND TO BE WITHIN LIMITS IAW SRM 53-40-43-02-01. PERFORMED ECI ON BLENDED AREA, NO CRACKS FOUND AT THIS TIME IAW NDTM PART 6 51-00-01.