What was found
CORROSION FOUND ON FRAME -39.00 BETWEEN STR 31S AND 31P. CORROSION REMOVED IAW SRM 51-21-00. PERFORMED U/T INSPECTION IAW NDTM 51-00-04. FOUND WITHIN LIMITS IAW NDT REPORT LINE ITEM NR 3 AND SRM 53-10-15, P59 STRUCT IDENT-01. RESTORED FINISH IAW SRM 51-25-05.