What was found
FIVE RIBS COMMON TO INNER AND OUTER EDGE BEAMS AFT PAX DOOR CORRODED. REMOVED RIBS AS SRM 51-42-05. INSTALLED 4 NEW RIBS AT AFT PAX DOOR REF SRM 51-42-05. NEW RIB COMMON TO INNER AND OUTER EDGE BEAMS AFT PAX DOOR LOC'N INSTALLED AT X 684.00 REF SRM 51-42-05. CORROSION NOT ALLOWED IAW E/C: 6-53-1160-AFT PAX DOOR. 5(EA) RIBS COMMON TO INNER AND OUTER EDGE BEAMS AFT PAX DOOR LOCATED AND DRILLED REF SRM 51-40-07. COMPLIED WITH FORM M184 FOR 5EA RIBS FOR THE AFT ENTRY LOWER SURROUND PN 85339514-101 (2EA), 85339515-101, 85339516-101, 85339517-101.