What was found
FWD PAX DOOR FWD ANGLE AT STA X6.7 STR 25 SHOWS EVIDENCE OF CORROSION. REMOVED AND REPLACED ANGLE IAW SRM 51-42-05, SRM 51-42-05-02-01, STEP 4D (3-10), SRM 51-40-07 AND SRM 51-40-15, STEP 6 H2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PAX DOOR FWD ANGLE AT STA X6.7 STR 25 SHOWS EVIDENCE OF CORROSION. REMOVED AND REPLACED ANGLE IAW SRM 51-42-05, SRM 51-42-05-02-01, STEP 4D (3-10), SRM 51-40-07 AND SRM 51-40-15, STEP 6 H2.