What was found
AIRSTAIR DOOR ANGLE AT STA X26.7 HAS EVIDENCE OF CORROSION. FOUND OUT OF LIMITS IAW SRM 51-21-00, 4(A)5 PAGE 3 AND DWG 85329576, DETAIL -104, REV -A REPLACED THE ANGLE IAW SRM 51-40-07, PAGES 201 TO 204.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRSTAIR DOOR ANGLE AT STA X26.7 HAS EVIDENCE OF CORROSION. FOUND OUT OF LIMITS IAW SRM 51-21-00, 4(A)5 PAGE 3 AND DWG 85329576, DETAIL -104, REV -A REPLACED THE ANGLE IAW SRM 51-40-07, PAGES 201 TO 204.