What was found
AFT PAX DOOR ENTRY EDGE BEAM FOUND CORRODED. REMOVED THE BEAM, IAW SRM 51-12-05 AND SRM 51-40-15. INSTALLED NEW BEAM IAW SRM 51-42-05 AND 51-40-15.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PAX DOOR ENTRY EDGE BEAM FOUND CORRODED. REMOVED THE BEAM, IAW SRM 51-12-05 AND SRM 51-40-15. INSTALLED NEW BEAM IAW SRM 51-42-05 AND 51-40-15.