What was found
BEAM FOR THE FWD EMERGENCY EXIT DOOR CORRODED. LOCATED & DRILLED NEW BEAM, IAW SRM 51-40-07. INSTALLED NEW BEAM IAW SRM 51-42-75.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BEAM FOR THE FWD EMERGENCY EXIT DOOR CORRODED. LOCATED & DRILLED NEW BEAM, IAW SRM 51-40-07. INSTALLED NEW BEAM IAW SRM 51-42-75.