What was found
CORROSION UNDER FINISH OF RT STRAKE LOWER MOUNTING AREAS. CORROSION UNDER FINISH OF RT STRAKE LOWER MOUNTING AREAS BLENDED/REMOVED REF SRM 51-21-00. C/W ET INSP ON REWORKED AREAS AS MARKED REF NDTM PT1 51-00-06. NO DEFECTS NOTED. FINISH REWORED TO REWORK AREAS UNDER RT STRAKE REF SRM 51-25-10. CORROSION UNDER FINISH OF RT STRAKE LOWER MOUNTING AREAS WITHIN LIMITS REF DWG 85360122. REWORKED AREAS NOTED IN ITEMS 2 AND 4. COMPLIED WITH FORM M-184.