What was found
FWD PAX DOOR HAS CORRODED UPPER FWD ANGLE. R & R THE ANGLE IAW SRM 51-41-05. LOCATED AND DRILLED THE HOLES TO THE ANGLE IAW SRM 51-40-07. C/W M-184 FORM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PAX DOOR HAS CORRODED UPPER FWD ANGLE. R & R THE ANGLE IAW SRM 51-41-05. LOCATED AND DRILLED THE HOLES TO THE ANGLE IAW SRM 51-40-07. C/W M-184 FORM.