What was found
FWD PASSENGER DOOR ANGLE AT STA X6.7, STR 25P FOUND CORRODED. REMOVED ANGLE IAW SRM 51-42-05-02-01, STEP 4E(2-8). INSTALLED NEW ANGLE IAW SRM 51-42-05-02-01, STEP 4D(3-10).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PASSENGER DOOR ANGLE AT STA X6.7, STR 25P FOUND CORRODED. REMOVED ANGLE IAW SRM 51-42-05-02-01, STEP 4E(2-8). INSTALLED NEW ANGLE IAW SRM 51-42-05-02-01, STEP 4D(3-10).