What was found
EDGE BEAM FOUND CORRODED AT SERVICE DOOR THRESHOLD. FABRICATED NEW INNER EDGE BEAM IAW DWG 85339543, REV A, SHT 1. INSTALLED IAW SRM 51-42-75 AND TC-6-53-1160.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EDGE BEAM FOUND CORRODED AT SERVICE DOOR THRESHOLD. FABRICATED NEW INNER EDGE BEAM IAW DWG 85339543, REV A, SHT 1. INSTALLED IAW SRM 51-42-75 AND TC-6-53-1160.