What was found
EDGE BEAM, HAS CORRODED ON EMERGENCY DOOR THRESHOLD. LOCATED AND DRILLED NEW EDGE BEAM IAW SRM 51-40-07-02-01. INSTALLED IAW SRM 51-42-05-02-01, STEP 4D (1).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EDGE BEAM, HAS CORRODED ON EMERGENCY DOOR THRESHOLD. LOCATED AND DRILLED NEW EDGE BEAM IAW SRM 51-40-07-02-01. INSTALLED IAW SRM 51-42-05-02-01, STEP 4D (1).