What was found
ON DEPARTURE, RT MAIN GEAR INDICATOR, GREEN LIGHT, REMAINED ILLUMINATED. ACCOMPLISHED MANUAL GEAR EXTENSION. RETURNED TO FIELD. LANDING UNEVENTFUL. FOUND THE FOLLOWING RELATED FAULTS IN PSEU, FAULT HISTORY D/N01A FAILED AND D/N02A FAILED, NO CURRENT RELATED FAULTS. COMPLIED WITH OPS TEST OF THE LANDING GEAR PRIMARY EXTENSION & RETRACTION SYS, REF AMM TASK 32-31-00-710-801 AND 6071001. OPS CHECK GOOD, COULD NOT DUPLICATE LOG ENTRY, NO FAULTS NOTED. AS PRECAUTION ACCOMPLISHED REPLACEMENT OF THE LANDING GEAR CONTROL PANEL. ALSO REF FIM TASKS 32-10-00-810-801, 32-73-31-810-843 AND 32-73-31-810-844. ACFT OK FOR CONTINUE SERVICE.