What was found
CORROSION FOUND ON INTERCOSTAL, MACHINED, BETWEEN FS X664.5 AND FS X669.5 AT STR 24P. REMOVED INTERCOSTAL BETWEEN FSX664.5 AND FSX669.5 STR 24P TO F.O.M. REF SRM 51-40-15 REPAIR-01. INSTALLED INTERCOSTAL BETWEEN FSX664.50 TO 669.50 STR 24P IAW SRM 51-40-15 REPAIR-01, PARA 1-6, A-H. REMOVED CORROSION ON INTERCOSTAL BETWEEN FSX664.5-X669.5, STR 24P, REF SRM 51-21-00 STRUCTURAL IDENT-02. C/W ET INSP & UT THICK TEST ON REWORKED INTEROCSTAL REF NDTM PT1 51-00-06 & 51-00-04. NO DEFECTS NOTED. MIN THICKNESS MEASURED=.102". MACHINED INTERCOSTAL BETWEEN FSX664.5 AND X669.5 HAS ORIGINAL THICKNESS AT BLENDED AREA OF .110". MIN THICKNESS MEASURED IS .102". MAXIMUM MATERIAL LOSS ALLOWABLE IS .010". MACHINED INTERCOSTAL IS WITHIN LIMITS IAW DWG 85339344, REV--, DATED 96/07/20. COMPLIED WITH FORM M-184.