What was found
ANGLE, COMMON TO PARTIAL WEB, RIB, AT FS X19.50 BETWEEN STR 25P AND LWR PAX DOOR THRESHOLD HAS CORROSION AND REQUIRES REPLACMENT TC:6-53-1160-FWD PAX DOOR. RECEIVED NEW ANGLE, PN 85329573-101. REMOVED CORRODED ANGLE FROM PARTIAL WEB AT X19.50 COMMON TO FUSELAGE SKIN UNDER MCD REF SRM 51-42-05. INSTALLED NEW ANGLE, PN 85329573-101 ON PARTIAL WEB AT X19.50, REF SRM 51-42-05, MOVED LOWER SURROUND. LOCATED AND DRILLED NEW ANGLE, PN 85329573-101 FOR FASTENER HOLES, REF SRM 51-40-07. COMPLIED WITH FORM M-184 CORROSION REPORT.