What was found
ANGLE, COMMON TO MACHINED WEB, RIB AT FS X 26.70 BETWEEN STR 25P AND LOWER PAX DOOR THRESHOLD HAS CORROSION AND REQUIRES REPLACEMENT IAW T/C 6-53-1160-FWD PAX DOOR. RECEIVED NEW ANGLE, PN 85329542-116. REMOVED CORRODED ANGLE FROM PARTIAL WEB AT X19.50 COMMON TO FUSELAGE SKIN UNDER MCD. REF SRM 51-42-05. INSTALLED NEW ANGLE, PN 85329542-116 ON MACHINED WEB AT X 26.70 , REF SRM 51-42-05, MOVED LOWER SURROUND. LOCATED AND DRILLED NEW ANGLE FOR FASTENER HOLES, REF SRM 51-40-07, ANGLE, PN 85329542. COMPLIED WITH FORM M-184, CORROSION REPORT.