What was found
SPLICES COMMON TO SEAT TRACK NR 5 AND NR 6 HAVE ELONGATED HOLES. DRILLED AND LOCATED HOLES COMMON TO SEAT TRACK NR 5 AND SPLICE MEMBERS REF SRM 51-40-07-02-01. DRILLED AND LOCATED HOLES COMMON TO SEAT TRACK NR 6 AND SPLICE MEMBERS AT FS 102.5 AND Y-9.250 REF SRM 51-40-07-02-01. INSTALLATION OF SPLICE MEMBERS COMMON TO SEAT TRACK NR 5 AND NR 6 ACCOMPLISHED ON JOB 5408321, OP 235.