Service difficulty report · Pump · Bombdr DHC8402

Difficulty date
December 10, 2015
Submitted
December 16, 2015
Operation
Air carrier
Aircraft
N413QX
Make and model
Bombdr DHC8402
Aircraft serial
4060
Part
Pump
Part number
6617303
Part serial
K0408
Condition
Failed
Location
Hyd System
Part time
20,159 hours, 21,430 cycles
Stage of operation
DE
How discovered
O
Nature of condition
K, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING DESCENT BEFORE GEAR EXTENSION, EXPERIENCED NR 2 HYD ISOLATION VALVE CAUTION WHILE RUNNING THE CHECKLIST NOTED 15 PERCENT NR 2 HYD QTY REMAINING. ACCOMPLISHED ALT GEAR EXTENSION IAW CHECKLIST AND MADE A NORMAL LANDING.SHUTDOWN AT GATE AND PINNED GEAR. ENG HYD LIGHTS DID NOT ILLUMUINATE, 5 PERCENT QTY REMAINING AT GATE. INSPECTED & FOUND NR 2 EDP LEAKING. R & R NR 2 EDP IAW AMM TASK 29-11-01-000-801, 29-11-01-400-801, & MCN 5114929232/1. C/W SIMPLFIED FLUSH OF THE NR 2 HYD SYS IAW TR-29-188 AMM TASK 29-10-00-617-803 PARA C. EDP OPS CHECKS GOOD. NO LEAKS NOTED. DEFERRED FULL FLUSH. RETURNED TO SERVICE.