What was found
CORROSION FOUND ON TYPE 2 EMERGENCY EXIT BEAM ASSY. REMOVED LOWER EMERGENCY EXIT DOOR DITCHING DAM IAW AMM 52-23-00. REMOVED 16 BOLTS FROM LOWER BEAM ASSY IAW SRM 51-40-07. REMOVED LOWER EDGE BEAM ASSY IAW SRM 51-42-05, SRM 51-40-07 AND SRM 51-42-90. INSTALLED ANCHOR NUTS ON NEW BEAM AND INSTALLED NEW BEAM, PN 85329514-101 IAW SRM 51-42-05, SRM 51-42-90 AND SRM 51-23-00. INSTALLED 16 BOLTS ON FLOOR RETAINER ATTACHING TO BEAM ASSY IAW SRM 51-41-05. INSTALLED LOWER DITCHING DAM DOOR IAW AMM 52-23-00 AND SRM 51-23-00.