What was found
EVIDENCE OF CORROSION ON DRAIN TROUGH SUPPORT ANGLES, PN 85329333-103, 2EA AT MCD LOWER SURROUND COMMON TO MACHINED INTERCOSTAL, STR 25P. REMOVED DRAIN TROUGH SUPPORT ANGLES, PN 85329333-103 FROM MACHINED INTERCOSTAL AT MCD LOWER SURROUND. REF SRM 51-42-05, 2 EA ANGLES. INSTALLED NEW DRAIN TROUGH SUPPORT ANGLES, PN 85329333-103 ON TO MACHINED INTERCOSTAL AT MCD LOWER SURROUND REF SRM 51-42-05 ANY DWG 85329330, RELEASE P REV A. ORIGINAL MATERIAL THICKNESS OF ANGLES, PN 85329333-103 IS .032 IN. IAW DWG 85329333, RELEASE P REV A REMAINING MATERIAL ON FWD ANGLE .029" AND .028" ON AFT ANGLE OUT OF LIMITS BEYOND ORIGINAL THICKNESS. RECEIVED 2 EA NEW ANGLES, PN 85329333-103. LOCATED AND DRILLED NEW ANGLES FOR FASTENER ANGLES REF SRM 51-40-07.