What was found
EVIDENCE OF CORROSION FOUND ON STRAP BETWEEN FS 301-321, STR 32P. BLENDED, REMOVED CORROSION ON INTERNAL STRAP BETWEEN FS X 301.0 TO FS X 321.0, STR 32P, REF SRM 53-00-00-02-20, PARA 6 A-B AND FIG 201, SHT 1 AND SHT 3. CW ET/UT INSP REF NDTM 51-00-06 + 51-00-04. NO DEFECTS NOTED. MIN THICK =.049" IN FWD AREA + .047" IN AFT AREA. ORIGINAL MATERIAL THICKNESS IS .050"; REMAINING MATERIAL AFTER BLEND IS .019 MIN ALLOWABLE MATERIAL ALLOWED ON STRAP IS .040. FOUND TO BE WITHIN LIMITS REF SRM 53-00-00-02-20, PG 203, FIG 201 SHT 1 NOTE 1, .047 AFT AREA. RESTORED FINISH ON STRAP BETWEEN FS X 301 TO FS X 321, STR 32P, REF SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-25-02-01.