What was found
FOUND CORROSION ON BEAM, PN 85329514-101 AND UNDER NUT PLATES AT EMERGENCY EXIT DOOR SURROUND. REMOVED FLOOR RETAINER, PN 85329515 REF SRM 51-41-00-00-01. INSTALLED FLOOR RETAINER, PN 853259515, REF SRM 51-41-00-00-01 AND DWG 85329511. REMOVED LOWER FORWARD EMERGENCY DOOR AT FS X 71.2- X 94.8 REF AMM 52-23-00-000-801. INSTALLED LOWER FORWARD EMERGENCY EXIT DOOR REF AMM 52-23-00-400-801. REMOVED 2 LOWER EMERGENCY DOOR STOP FITTINGS, PN 85329283-001 AT FS X88.2, FS X 77.38, Y40, REF SRM 51-41-00-00-01. INSTALLED 2 LOWER EMERGENCY DOOR STOP FITTINGS, PN 85329283-001 REF SRM 51-41-00-00-01. REMOVED CORRODED EDGE BEAM, PN 85329514-101, REF SRM 51-42-05-02-01. INSTALLED NEW EDGE BEAM, PN 85329514-101, REF SRM 51-42-05-02-01 AND DWG 85329511, REV D. LOCATED & DRILLED FASTENER HOLES FOR NEW REPLACEMENT EDGE BEAM, PN 85329514-101, REF SRM 51-40-07-02-01. PERFORMED FUNCTIONAL TEST OF THE LOWER FORWARD EMERGENCY DOOR REF AMM 52-23-00-720-801, FUNCTION TEST GOOD.