What was found
FLAP POWER CAUTION LIGHT DURING FINAL APPROACH, WHEN SELECTING FLAPS 35 DEG. CANCELLED APPROACH KEEPING THE AIRSPEED UNDER FLAPS 15 SPEED LIMITATION AND RAN THE CHECKLIST. THE FLAP POWER CAUTION LIGHT ILLUMINATED AGAIN, AFTER THE FLAPS CONT CICUIT BREAKER RESET. EXECUTED A NORMAL FLAP 15 LANDING. NO CURRENT FAULTS IN CDS. CYCLED A/C POWER PERFORMED OPS TEST OF WING FLAPS IAW AMM 27-50-00-710-801. OPS TEST PASSED. EXTENDED AND RETRACTED THE FLAPS FIVE TIMES, PERFORMED GVI O FLAPS FROM GROUND WHILE AT 35 DEG. NO DEFCETS NOTED. "FLAP POWER" CAUTION DID NOT ILLUMINATE AT ANY TIME. FLAPS OPERATE NORMAL. NO PARTS REPLACED.