What was found
APU FAILED TO START. FUEL DRIPPING AND STRONG FUEL ODOR. PERFORMED OPERATIONAL TEST OF APU IAW AMM 49-00-00-710-801 SEVERAL TIMES WITH NO DEFECTS. COULD NOT DUPLICATE. RETURNED TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU FAILED TO START. FUEL DRIPPING AND STRONG FUEL ODOR. PERFORMED OPERATIONAL TEST OF APU IAW AMM 49-00-00-710-801 SEVERAL TIMES WITH NO DEFECTS. COULD NOT DUPLICATE. RETURNED TO SERVICE.