What was found
DURING APPROACH WHEN SELECTING FLAPS 35, THE FLAPS STUCK AT 16 & THE FLAP POWER CAUTION ILLUMINATED. FLAP CONT CIRCUIT BREAKER HAD NOT TRIPPED, RESET ONCE IAW THE E & A CHECKLIST. FLAP POWER REMAINED ILLUMINATED. COMPLIED WITH E & A CHECKLIST LANDED WITH FLAPS 15 NORMALLY WITHOUT INCIDENT. FLAP HANDLE WAS OPERATED SLOWLY IAW FSM INSTRUCTIONS. NO PRESENT FAULTS NOTED IN CDS. PERFORMED FLAP NVM RESET. C/W FIM TASK 27-50-00-810-802 STEPS 1 THRU 3A(3). OPERATIONAL TEST OF WING FLAPS GOOD IAW AMM TASK 27-50-00-710-801. CYCLED WING FLAPS 3 TIMES. NO FAULTS NOTED, NO FURTHER CAUTION LIGHT NOTED.