What was found
LEFT MAIN GEAR DOOR LIGHT CONTINEOUSLY FLASHING THROUGHTOUT THE FLIGHT, COULD FEEL A THUMP EACH TIME THE CAUTION LIGHT CYCLED. GEAR DOWN NO MORE CYCLING. INTERROGATED PSEU. FOUND LGDRCL SENSOR UNREASONABLE FAR. RIGGED LGDRCL PROXIMITY SENSOR IAW AMM TASK 32-61-06-830-801. CYCLED LMLG DOORS SEVERAL TIMES. INDUCTANCE VALUE IS GOOD PER AMM 32-61-00-280-801. NO DEFECTS IN PSEU. VERIFIED RIGGING AND INDUCTANCE VALUES OF THE LGUPLK LGDLK 1 AN LGDLK2 SENSORS. CHECK GOOD IAW 32-61-06-830-801 AND 32-61-00-280-801. RETURNED TO SERVICE.