What was found
NOSE GEAR RED UNSAFE LIGHT REMAINED ILLUMINATED FOR 15 SECONDS AFTER MAIN LANDING GEAR COMPLETED NORMAL CYCLE. AFTER 15-20 SECONDS OF NOSE RED ILLUMINATED, NOSE GREEN ILLUMINATED AND RED EXTINGUISH. PERFORMED RETRACTION & EXTENSION OF THE NOSE LANDING GEAR IAW 32-31-00-867-802, FOUND FAULT CODE "NGDRCL NEAR GAP TO SMALL"ON PSEU. NGDCL IN PSEU INDUCTANCE SHOWED 10.3 MH, RIGGED NGDRCL PROXIMITY SENSORS IAW 32-61-06-830-801 & 32-61-00-280-801, NOSE GEAR "RED" UNSAFE LIGHT DID NOT REMIAN ILLUMINATED FOR 15 SECONDS AFTER MAIN LANDING GEAR COMPLETED NORMAL CYCLE. NO FAULTS FOUND IN PSEU. RETURNED TO SERVICE.