What was found
FLIGHT ATTENDENT REPORTED DURING CRUISE THAT THE GALLEY SERVICE DOOR HANDLE HAD FLOPPED INBOARD. THE DOOR SYNOPTIC PAGE SHOWED THE DOOR TO BE CLOSED AND THERE WERE NO CHANGES IN THE PRESSURIZATION. INSPECTED IAW AMM 52-41-01-400-801, FIG 409, ITEMS 5, AND 8 AND FOUND A BOLT FASTENING HANDLE SPRING TO HANDLE SHAFT HAD FAILED. INSTALLED SERVICEABLE HARDWARE IAW AMM 52-41-01-400-801 PAR. 1A-3A, 4C, AND 5B-5G. PERFORMED A FUNCTIONAL CHECK OF AFT SERVICE DOOR IAW AMM 52-41-00-720-801, CHECKED GOOD. SEARCHED INTERIOR OF DOOR VIA BORESCOPE AND RETRIEVED FAILED HARDWARE. NO FURTHER DEFECTS NOTED. RETURNED TO SERVICE.