What was found
CORROSION ON FRAME REINFORCEMENT FLANGE AND STRINGER 24R ATTACHING CLEAT BS 547.5. REMOVED THE REINFORCEMENT AND ATTACHING CLEAT IAW SRM 51-42-05-02-01. INSTALLED A NEW REINFORCEMENT AND CLEAT IAW SRM 51-42-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.