As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD DRAFT BULKHEAD CONTACTS THE DITCHING DAM PREVENTING ITS LOWERING. REMOVED AND REPLACED AIRSTAIR DOOR DITCHING DAM WITH A NEW UNIT FROM STOCK. REF 8/400 AMM 25-62-01-000-801 FOR REMOVAL AND 25-62-01-400-801 FOR INSTALLATION. OPS CHECKED GOOD.