What was found
CORRROSION FOUND ON STRINGER 24S AT BS 168. PERFORMED A PERMANENT SPLICE REPAIR TO STRINGER 24S BETWEEN BS 156 AND 176 IAW RD 84-53-8177.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORRROSION FOUND ON STRINGER 24S AT BS 168. PERFORMED A PERMANENT SPLICE REPAIR TO STRINGER 24S BETWEEN BS 156 AND 176 IAW RD 84-53-8177.