What was found
CORROSION FOUND ON STRINGER 24P, BETWEEN BS 281 AND 301. PERFORMED A PERMANENT REPAIR TO THE STRINGER IAW RD 84-53-8178 ISSUE.1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON STRINGER 24P, BETWEEN BS 281 AND 301. PERFORMED A PERMANENT REPAIR TO THE STRINGER IAW RD 84-53-8178 ISSUE.1.