What was found
FRAME FLANGE ON AFT SIDE OF BS 301 BETWEEN STRINGERS 31 AND 32R HAS EVIDENCE OF SURFACE CORROSION. REMOVED & BLENDED ALL CORROSION IAW SRM 53-00-00, REPAIR 09. FOUND TO BE WITHIN LIMITS IAW SRM 53-00-00-02-09, REPAIR 09. RESTORED THE FINISH IAW SRM 51-21-10, REPAIR 01, 51-25-10, REPAIR 01, & 51-25-15, REPAIR 01.