What was found
STRINGER 25L HAS EVIDENCE OF CORROSION FORE & AFT OF FRAME BS 196. REMOVED AND BLENDED CORROSION ON THE FRAME IAW SRM 53-00-00, REPAIR -09. PERF'D E/T AND U/T INSP ON STR 25L BLEND OUT IAW NDTM 51-00-04 AND 51-00-06. OUT OF LIMITS IAW SRM 53-00-00-02-09 AND DWG #85327235. CUT OUT DAMAGED PORTION OF STRINGER IAW RD 8/4-53-8270 ISSUE 1. FABRICATED LOCATED, DRILLED AND DEBURRED NEW SPLICE ANGLE AND REPAIR PACKER IAW RD 8/4-53-8270. FINISHED NEW PART, ALODINED AND PRIMED IAW RD 8/4-53-8270. INSTALLED THE REPAIR IAW RD 8/4-53-8270. RESTORED FINISH TO REWORKED AREA AT STR 25P AT STA X.196.0 REF RD 8/4-53-8270.