What was found
EVIDENCE OF CORROSION ON FLANGES ON FWD SIDE OF FRAME, FS 1.000 BETWEEN ON STRINGERS 31 & 33R. BLENDED CORROSION IAW SRM 51-21-00. COMPLIED WITH ET & UT INSPECTION IAW NDTM 51-00-06 & 51-00-04. NO DEFECTS NOTED. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00. COMPLIED WITH RD84-53-8471. R & R THE FRAME SPLICE IAW SRM 51-40-07, RD84-53-8471, ISSUE 2. C/W ET INSP PER RD84-53-8471 ISSUE 2. NO DEFECTS NOTED. LOCATED & DRILLED REPAIR SPLICE COMMON TO STR 28 REF RD84-53-8471. LOCATED & DRILLED REPAIR STRAP COMMON TO STR28R REF RD84-53-8471 ISSUE 2. REF SRM 51-42-05 & INSTALLED SPLICE & STRAP COMMON TO STR 28S X 1.0 APPROX IAWRD84-53-8471 REV 2006-08.INSTALLED STRAP COMMON TO STR33 X 1.0 REF SRM 51-42-05. RESTORED FINISH PER SRM 51-25-10, 51-25-15.