What was found
SHEART TIE AT BS 439, STRINGER 24L HAS EVIDENCE OF CORROSION. REMOVED CORROSION IAW SRM 51-21-00, STEP 4 (2) (A), STRUCT IDENT -02. COMPLIED WITH ET & UT INSPECTION IAW NDTM 51-00-06 & 51-00-04. NO DEFECTS NOTED. FOUND WITHIN LIMITS IAW DWG 85328131, REV B. RESTORED FINISH IAW SRM 51-25-10-02-01, & 51-25-15-02-01.