What was found
CORROSION ON STR 24P BETWEEN FS 373.00 + 401 LT SIDE. RIVETS REMOVED TO BLEND CORROSION IAW SRM 51-42-05. STRINGER FOUND TO BE BEYOND LIMITS, STRINGER 24P AT FS 373.00 TO FS 413.00 REMOVED AND REPLACED WITH NEW PART IAW SRM 51-40-05, 51-40-07, 51-40-15, 51-42-05 AND 51-42-15.