Service difficulty report · Connector · Bombdr DHC8402

Difficulty date
January 6, 2018
Submitted
January 8, 2018
Operation
Air carrier
Aircraft
N441QX
Make and model
Bombdr DHC8402
Aircraft serial
4348
Aircraft time
15,613 hours, 16,589 cycles
Part
Connector
Condition
Disconnected
Location
Control Valve
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NR 2 BLEED HOT CAUTION AT 80 KTS, AFTER TAKEOFF ACFT DID NOT PRESSURIZE. REMOVED FROM SERVICE. INTERROGATED CDS AND FOUND PACK CONTROL VALVE FLAGGED. INSPECTED THE PACK CONTROL VALVE AND FOUND CONNECTOR NOT SECURE. SECURED THE CONNECTOR AND COMPLIED WITH AND OPS TESTED GOOD IAW 21-52-01-861-001. PRESSURIZED THE ACFT IAW 21-31-00-710-803 PRESSURIZATION CHECKED GOOD. OPS CHECKED THE BLEEDS IAW 36-11-00-710-801. NO FAULTS NOTED AND NO FAULTS IN CDS. ACFT OK FOR RETURN TO SERVICE.