What was found
EMERGENCY LIGHTS REMAINED ON AFTER ACFT POWERED DOWN, WOULD TURN OFF AFTER EXTERNAL POWER APPLIED. REMOVED AND DISASSEMBLED ADVISORY PASSENGER WARNING PANEL IAW AMM 31-51-33-000-801 STEPS 1-4A(6). COMPLETED REMOVAL OF ADVISORY PASSENGER WARNING PANEL AND EMERGENCY LIGHT SWITCH IAW AMM 31-51-33-000-801 AND INSTALLED A NEW SWITCH AND ORIGINAL ADVISORY PASSENGER WARNING PANEL IAW AMM 31-51-10-400-801. CHECKED GOOD, ALSO REMOVED AND REPLACED THE F/A EMERGENCY LIGHT SWITCH BODY MODULE WITH A SERVICEABLE UNIT IAW AMM 33-51-05-000-801, AND 33-51-05-400-801, OPS CHECKED GOOD.