As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLAP POWER CAUTION ILLUMINATED DURING FINAL, SELECTING FLAPS FROM 5 TO 10. RAN E & A CHECKLIST, FLAP POWER CAUTION EXTINGUISGED. NO FURTHER ISSUES, FLAPS OPERATED NORMALLY. LANDING UNEVENTFUL. REMOVED FROM SERVICE. PERFORMED OPERATIONAL TEST OF THE WING FLAPS IAW AMM TASK 27-50-00-710-801. OPS TEST PASSED. RETURNED TO SERVICE. COULD NOT DUPLICATE.