What was found
ON FINAL APPROACH WHILE SELECTING FLAPS 5, THE FLAP INDICATOR, INDICATED BETWEEN 0 DEGREES AND 5 DEGREES AND THE FLAP DRIVE CAUTION LIGHT ILLUMINATED. AFTER RUNNING THE E/A CHECKLIST AND PUTTING THE FLAPS TO 0 DEGREES, THE FLAPS RETRACTED NORMALLY AND THE FLAP DRIVE CAUTION EXTINGUISHED. PERFORMED A GO-AROUND. ON SUBSEQUENT APPROACH, THE FLAPS EXTENDED TO 35 DEGREES NORMALLY AND A NORMAL LANDING WAS ACCOMPLISHED. REMOVED FROM SERVICE. REMOVED AND REPLACED THE NR 2 FLAP ACTUATOR IAW 27-52-16-000-801, AND 27-52-16-400-801, OPS AND FUNCTIONAL CHECKED GOOD, NO DEFECTS NOTED. RETURNED TO SERVICE.