Service difficulty report · Warning System · Bombdr DHC8402

Difficulty date
March 4, 2019
Submitted
March 4, 2019
Operation
Air carrier
Aircraft
N444QX
Make and model
Bombdr DHC8402
Aircraft serial
4355
Aircraft time
17,626 hours, 18,849 cycles
Part
Warning System
Condition
False Activation
Location
Cockpit
Part time
25,989 hours, 27,876 cycles
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CLIMB OUT OF FL180 WE GOT INTERMITTENT FUSELAGE DOOR MASTER WARNING. RAN CHECKLIST AND DIVERTED TO GEG. DESCENDING OUT OF 180 LIGHT STAYED OFF. DOOR SHOWING OPEN ON DOORS PAGE WAS EMERG EXIT TYPE II/III. DIVERTED. LANDING UNEVENTFUL. REMOVED FROM SERVICE. INDUCTANCE VALUE CHECKED IN THE PSEU IAW AMM 32-61-00-280-801 OF THE EMG DOOR SENSOR EDRCLLK, SENSOR CHECKED NOMINAL, FAULT CODE UNRSNABL FAR U00 LOGGED INTO PSEU FOR PREVIOUS LEG. PRESSURIZED AIRCRAFT IAW 21-00-00-863-801, COULD NOT DUPLICATE DOOR MASTER WARNING, REMOVED AND REPLACED THE PSEU IAW 32-61-01-000/400-801 AS A PRECAUTIONARY MEASURE. AIRCRAFT RETURNED TO SERVICE.