What was found
SUSPECTED CORROSION ON EMERGENCY EXIT LOWER THRESHOLD BEAM. REPLACED LOWER THRESHOLD BEAM ON EMERGENCY EXIT DOOR IAW SRM 51-42-05. 51-42-45 AND 51-41-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SUSPECTED CORROSION ON EMERGENCY EXIT LOWER THRESHOLD BEAM. REPLACED LOWER THRESHOLD BEAM ON EMERGENCY EXIT DOOR IAW SRM 51-42-05. 51-42-45 AND 51-41-05.